Ideal F2 Fault Code
F2. Flame loss Check the other gas appliances in the house are working to confirm a gas supply is present on the property. If the other...

Richard Weedon
Sep 18, 20221 min read
8 views
0 comments


Ideal F1 Fault Code
F1Low water pressure Check the system water pressure is set between 1 and 1.5 bar on the pressure gauge. To re-pressurise the system...

Richard Weedon
Sep 18, 20221 min read
7 views
0 comments


Landlord Carbon Monoxide New Regulations
!st October 2022 What type of carbon monoxide alarm is required? The regulations do not stipulate the type of alarms (such as mains...

Richard Weedon
Sep 18, 20222 min read
7 views
0 comments


Boiler Quickies, Gas meter & expansion vessel quick tips, poor access easy fix must have tool
Boiler Quickies Boiler expansion vessel poor access easy way to access the valve, gas meter tightness test, 10mm socket is the easiest...

Richard Weedon
Mar 27, 20211 min read
22 views
0 comments


Ideal Independent boiler, drain down ready to replace PRV, expansion vessel plate heat exchanger
Boiler Quickies To drian down this boiler you need a big philips screwdriver or a 13mm spanner, a ratchet spanner is best, you could...

Richard Weedon
Mar 27, 20211 min read
19 views
0 comments


Find fault codes on Vailliant Ecotec Boilers F61. F62. Fault code history Boiler Quickies
Boiler Quickies Boiler quickies, how to find I would fault codes on your boiler Vailliant Ecotec. Bring up the last five codes. Boiler...

Richard Weedon
Mar 27, 20211 min read
12 views
0 comments


How to check your immesrsion heater with a multimeter. Boiler Quickies
How to check your immesrsion heater with a multimeter. Be careful, make sure you carry out all safety checks, if in doubt get a qualified...

Richard Weedon
Mar 27, 20211 min read
2 views
0 comments


Immersion Element, quick check to see if it is working, all you need is an electrical screwdriver.
Be careful, there are live electrics here. Take all relevent precautions to ensure your safety, If in doubt consult a qualified...

Richard Weedon
Mar 27, 20211 min read
1 view
0 comments


How to put a vaillant into test mode, the purge program is important, this is the P0 program
How to put a vaillant into test mode, the purge program is important, this is the P0 program, but you can also access P1 & P2. Boiler...

Richard Weedon
Mar 27, 20211 min read
2,692 views
0 comments


Override a port valve to get your heating hot water back on. Boiler Quickies. Enfield North London
Override a port valve to get heating hot water back on. Gas Safe engineer. Cheshunt. Enfield ware. Gas safe landlord gas checks...

Richard Weedon
Mar 27, 20211 min read
3 views
0 comments


Vaillant, how to check the pressure on your boiler using the digital display Boiler Quickies
To check the pressure on your boiler using the digital display Press "i" and then "-"

Richard Weedon
Mar 27, 20211 min read
15 views
0 comments


Vaillant TurboMax Faulty PCB or Control panel. Boiler Quickies
Vaillant TurboMax, If you display is not working it could be the Main PCB or the small control panel, this is how to test it with a...

Richard Weedon
Mar 27, 20211 min read
5 views
0 comments


Harlow Gas Inspections
Landlord gas safety check, carried out for a freeholder as Harlow council require this for all multi occupancy buildings, blocks of...

Richard Weedon
Mar 20, 20211 min read
1 view
0 comments


Landlord Gas Inspection FAIL
This boiler flue is not sealed correctly and fails a Landlord gas safety check, carried out for a freeholder as Harlow council require...

Richard Weedon
Mar 20, 20211 min read
2 views
0 comments


Freeholder Gas Gafety Check Harlow
Freeholder Gas Gafety Check is the same as a Landlord gas safety check, carried out for a freeholder as Harlow council require this for...

Richard Weedon
Mar 20, 20211 min read
4 views
0 comments


Vaillant Fault Code F.75
F.75 Fault: Pump/ water shortage: Water pressure sensor and/or pump defective, air in the heating installa- tion, insufficient water in...

Richard Weedon
Feb 28, 20211 min read
6 views
0 comments


Vaillant Fault Code F.74
F.74 Fault: Water press. sensor: The line to the water pressure sensor has a short circuit to 5 V/24 V or internal fault in the water...

Richard Weedon
Feb 28, 20211 min read
10 views
0 comments


Vaillant Fault Code F.73
F.73 Fault: Water press. sensor: Interruption/short circuit of water pressure sensor, interruption/short circuit to GND in supply line to...

Richard Weedon
Feb 28, 20211 min read
48 views
0 comments


Vaillant Fault Code F.72
F.72 Fault: Flow/return sensor: Flow/return NTC temperature difference too great → flow and/or returntemperature sensor defective

Richard Weedon
Feb 28, 20211 min read
5 views
0 comments


Vaillant Fault Code F.71
F.71 Fault: Flow sensor: Flow temperature sensor signalling constant value:– Flow temperature sensor incorrectly positioned at supply...

Richard Weedon
Feb 28, 20211 min read
78 views
0 comments